Systems Troubleshooting: 6-2
The engine turns over but will not start.
2.
Possible Cause
Solution
2.1. The recovery tank is full
Drain the tank.
2.2.
The recovery tank float is
faulty.
Inspect the float. Repair or replace as necessary.
2.3. The engine ignition
system in faulty.
Refer to a qualified service technician for further
troubleshooting.
2.4. fuel is not reaching the
carburetor.
Test for power to the fuel pump. Refer to electrical
Section.
If power is present, inspect the fuel pump. Replace if
necessary.
Inspect the fuel lines between the source and the
carburetor. Repair or replace as necessary.
2.5.
The engine is flooded.
Remove spark plug and dry.
2.6.
.
The spark plugs are worn
or dirty.
Inspect and replace as necessary.
2.7. None of the above.
Refer to a qualified service technician for further
troubleshooting.
engine should be adjusted to run at 3,000 rpm under a vacuum load of 14” Hg.
The engine will not come up to normal operating rpm
3.
Possible Cause
Solution
3.1. excessive load on the
engine.
Inspect and clean the recovery tank filters.
Inspect the recovery tank to the blower hose. Repair
or replace as necessary.
3.2. excessive back pressure
on the engine exhaust.
Inspect for blockage in the exhaust system. Clean or
replace as necessary.
Содержание Titan H2O Kubota
Страница 2: ......
Страница 6: ...Titan H2 O Owner s Manual iv...
Страница 34: ...Machine Maintenance 4 8...
Страница 40: ...Electrical System 5 6...
Страница 46: ...Systems Troubleshooting 6 6...
Страница 48: ...Assemblies and Parts Lists 7 2 Machine Assembly View 1 of 4 Figure 7 1 610 050 743 4 5 2 X 6 7 1 11...
Страница 49: ...7 3 Assemblies and Parts Lists Machine Assembly View 2 of 4 Figure 7 2 610 050 743 11...
Страница 58: ...Assemblies and Parts Lists 7 12 Engine Assembly View 2 of 3 Figure 7 9 610 004 743 13 6 7 16 1...
Страница 59: ...7 13 Assemblies and Parts Lists Engine Assembly View 3 of 3 Figure 7 10 610 004 743 26 15 11 17 19...
Страница 80: ...How to Order Parts 8 2...
Страница 82: ...Warranty Information 9 2...