FluidAqua Mobil - FAM 10
Model Code
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 70 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Model Code
FAM -
10 - M - 1 - A/1900 - 060 - DM -
02 -
S - z - 1
Product
FAM = FluidAqua
Mobil
Size
10
= 10 l/min, 50 Hz / 12 l/min, 60 Hz
10/15 = 15 l/min, 50 Hz / 18 l/min, 60 Hz
Operating fluid
M
= Mineral oil – NBR seals, checked with
mineral oil
I
= Insulation oil – NBR seals, checked with
insulation oil
X
= HFD-R phosphoric acid ester fluids –
FPM seals checked with HFD-R fluid*
P
= Aviation phosphoric acid esters e.g.
Skydrol
®
or Hyjet
®
checked with Skydrol®*
B
= Readily biologically degradable (on ester
base) – FPM seals
*Residues of test liquid will remain in the unit after
testing.
Mechanical type
1 =
stationary
2 =
mobil
Voltage / Frequency / Power supply
a
= 400 V, 50 Hz, 3 Ph+PE
B
= 415 V, 50 Hz, 3 Ph+PE
C
= 200 V, 50 Hz, 3 Ph+PE
D
= 200 V, 60 Hz, 3 Ph+PE
E
= 220 V, 60 Hz, 3 Ph+PE
F
= 230 V, 60 Hz, 3 Ph+PE
G
= 380 V, 60 Hz, 3 Ph+PE
H
= 440 V, 60 Hz, 3 Ph+PE
J
= 230 V, 50 Hz, 3 Ph+PE
K
= 480 V, 60 Hz, 3 Ph+PE
L
= 220 V, 50 Hz, 3 Ph+PE
M
= 230 V, 50 Hz, 1 Ph+PE
N
= 575 V, 60 Hz, 3 Ph+PE
O
= 460 V, 60 Hz, 3 Ph+PE
X =
other
voltage
Filter size fluid filter
05 =
OLF-5
Filter material of element
DM =
Dimicron
®
z =
without
filter
element
Filtration rating
02 =
2
µm
05 =
5
µm
10 =
10
µm
20 =
20
µm
z =
without
filter
element
Type of vacuum pump
S
= Standard – rotary vane vacuum pump
Instrumentation
z
= Without
A
= AquaSensor (AS)
C
= ContaminationSensor
(CS)
AC
= Aqua ContaminationSensor (CS only with measured value
display)
Modification number
1
Supplementary details
Without details = standard
V
= Sealing
material
Viton