FluidAqua Mobil - FAM 10
Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 56 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Performing Maintenance
WARNING
Operating pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
Before performing any maintenance work, pull out the plug on the FAM and wind up
the power cord to prevent the unit from being switched on again.
The prescribed adjustment, maintenance/servicing and inspection work is to be
conducted in accordance with the respective schedules.
The unit is to be disconnected from the power supply and protected against being
inadvertently switched back on when performing any maintenance, servicing,
inspection or repair work.
Once maintenance work is complete, check that the safety devices are still working
properly. Any screwed fittings which have been undone/removed are to be checked
to see that they have been properly resecured.
24 hrs.
or
daily
500 hrs.
or
monthly
3000 hrs.
or
twice per
year
Check for leaks
X
Visual check of electrical
equipment
X
Clean the suction screen
X