Starting up the FAM
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 38 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Venting the filter housing
WARNING
Hot fluid
Danger of burns
►
Note that hot fluid may exit during bleeding.
NOTICE
Air in the fluid filter
The filter element is not utilized completely
►
Bleed the fluid filter after each shut-down / filter element replacement.
The fluid filter is to be bled through the air-vent plug until fluid emerges. Using an
Allen wrench carefully open the air-vent plug in the cover.
Shut off FAM
Press the
key. Now the system starts the run-down phase:
FluidAqua operating
Run-down
1. The inlet valve closes
2. The vacuum pump switches off
3. The filter-pump unit runs until the vacuum chamber is emptied.
Wait until the message appears on the display. Now move the main switch to the
position "0". The system is now switched off.
Ready for operation
--> Press start