Electrical Connection of the FAM
DANGER
Electric shock
Danger of fatal injury
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
Check that the voltage and frequency information on the type label coincides with
the voltage supply present.
If a plug is present on the FAM or if you mount a plug, then operate the FAM from a
correspondingly fused socket.
For safety, run a selective calculation. For safety, use automatic fuses with
triggering characteristic "C".
The rotating field of the connection socket must be clockwise. If this is not the case,
then the phases can be rotated in the 16A / 32 A connection plug with the aid of the
phase changing switch in the plug. For the 63A version, the two phases must be
switched on the terminal block S0 (e.g. L1 and L2).
A phase sequence relay checks the correct phase sequence after switch-on. In the
event of an incorrect phase sequence, error message no. 29 is shown on the control
panel.