FluidAqua Mobil – FAM 10/15 +AS1000
Maintenance
HYDAC Filtertechnik GmbH
en
Page 69 / 80
Maintenance
Visual checks
Regular visual inspection of all hoses and conduits for leakage.
Regular visual inspection of the electrical apparatus for possible damage to lines,
plugs, sensors or cables and/or devices in the control cabinet.
Regular visual inspections of filling level, vacuum pump
Before carrying out any maintenance work the FAM must be shut down safely. This
means:
1. Main switch in position "0",
2. Power cord disconnected.
3.
Mains cable wound around cable drum apparatus present on the FAM. (This
last as a protection against switching back on again!)
Vacuum pump
The first oil change must be carried out after 100 operating hours. Later oil change
intervals are dependent on operating conditions.
The oil must be changed after 500 - 2000 hours of operation, but at least semi-
annually. The oil may need to be changed sooner than that in the event of heavy
contamination.
After 2000 hours of operation or if oil mist escapes from the separator during the
operation of the pump the exhaust filter must be changed.
BEWA FAM10 3417360 en.doc
2008-06-06