FluidAqua Mobil – FAM 10/15 +AS1000
Error messages
HYDAC Filtertechnik GmbH
en
Page 65 / 80
Safety thermostat
Yes
6
No
Heater defective,
Contact the HYDAC Service
Department
Error appears
again
No
Main switch to "Off", disconnect FAM from power
source
Reconnect mains switch, main switch to "On",
start device with "F1" key
Check the cable of the safety
thermostat
up to the SPS;
check the setting value of the
safety thermostat, nominal: 80°C
Error?
7
Failure repaired
Yes
Replace K7 relay (see circuit dia-
gram)
Message:
Heater safety thermostat triggered.
BEWA FAM10 3417360 en.doc