FluidAqua Mobil – FAM 10/15 +AS1000
FAM Set-up and Connection
HYDAC Filtertechnik GmbH
en
Page 25 / 80
Preparing the Vacuum Pump
As a basic rule, the rotary vane vacuum pump is not filled with oil at the time the
FAM is delivered.
NOTE
Operating the FAM without oil in the vacuum pump will cause irreparable
damage to the pump.
The rotary vane vacuum pump must be checked for sufficient filling be-
fore commissioning.
To fill the rotary vane vacuum pump, the
oil is filled in through the filling screw plug
(1)
until the oil filling has risen above the
MIN marking in the viewing glass
(2)
.
Exceeding the MAX marking will lead to
fault messages on the control panel.
1
2
The oil quantity between the MIN/MAX markings is
≈
0.3 liters
The water level is monitored automatically by the integrated float switch while the
FAM is in operation. A message will appear on the control panel when the MIN filling
level has been reached.
Synthetic vacuum pump oil in accordance with DIN 51506, Group VDL, ISO VG100
must be used for topping up.
This can be ordered from HYDAC under the part. no.:
Description
Part no.:
Vacuum pump oil VE101
DIN 51506, Group VDL, ISO VG100, synthetic
1 liters
06018128
Vacuum pump oil VE101
DIN 51506, Group VDL, ISO VG100, synthetic
5 liters
06018129
BEWA FAM10 3417360 en.doc