Performing inspection / maintenance
Changing the CTU 1xx0 filter elements
Inline Filter LF60
Item Designation
1
Filter element including
O-ring (2)
2
O-ring
3
O-ring
4
Support ring
5
Sealing ring
6
O-ring
-
Repair kit, consisting of:
O-ring [2], O-ring [3], support ring
[4], sealing ring [5], O-ring [6]
Tools needed:
Open-ended wrench, size 27 mm (for the filter bowl)
To change the filter, proceed as follows:
1. Remove the right side paneling.
To do this, turn the locks 90° in a
counterclockwise direction using the
four-sided hollow socket key. Flip the
side paneling away from the CTU and
up out of the lower guide.
Remove the ground bond wire.
2. Unscrew the contamination retainer
(filter bowl) in a counterclockwise
direction using a size 27 open-ended
wrench and remove it.
The filter bowl contains test liquid.
Drain this into a suitable receptacle (> 1
liter) and dispose of it properly (in an
CTU 1000 Series
en(us)
Page 62 / 92
BeWa CTU1000 3229578p en-us 2017-04-25.doc
2017-04-25