9 Dismantling
the
FCU
CAUTION
Hot fluid at the OUTLET
Before removing, allow the FCU to cool off
When dismantling the FCU, make sure to follow the sequence specified here:
To stop the measurement, press the red "Pump off" button.
Pull the plug and disconnect the electrical connection
Unscrew the inlet hose at the measurement point of the hydraulic system
Remove the FCU INLET hose
To remove the quick-action coupling, place your hand around the hose and
pull back the outer ring of the coupling. The coupling releases from the nipple
without the use of a tool. The fluid remaining in the hose must be drained into
a suitable receptacle and disposed of properly. Fluid may still exit from the
OUTLET after the unit has been shut off.
OUTLET
The FCU can now be removed and closed.
Pack the hoses, cable and other FCU accessories into the bag on the cover of
the FCU.