Using the FCU
The FCU 1000 is a portable service unit for the temporary measurement of particulate
contamination in hydraulic systems. With the integrated AquaSensor AS 1000, the
measurements can be expanded to include the saturation level of water in hydraulic media in
% and temperature.
The installed pump and hoses included in delivery can be applied to:
•
Control circuits
•
Pressure circuits
•
non-pressurized tanks
Performance Features:
•
Particulate contamination detection by use of an optical measurement cell
•
Applicable for hydraulic fluids 10 … 350 mm²/s / 16 … 1622 Sus (ISO VG 68)
•
Integrated AquaSensor AS 1000 for the measurement of humidity and temperature
•
Automatic measurement and display of cleanliness ratings as
ISO 4406:1987; NAS 1638
ISO 4406:1999; SAE AS 4059 (D)
•
Measurement Ac/- ½ ISO code
•
Supply voltage 24 V DC / 4 A
•
Operating pressure max. 45 bar / max. 650 psi, operating pressure with pressure
adaptor max. 345 bar / max. 5000 psi
•
Integrated pump for the automatic control of oil flow