FluidControl Unit - FCU 1000 Series
HYDAC Filtertechnik GmbH
en
Page 30
BeWa_FCU1000_3371346a_en.doc
2007-12-04
1)3
Continuous measurement and display of the
measurement value as relative humitidy of the fluid in
% saturation
7.1.1.5
Measured variable "Temperature"
Display
Description
3/8
Continuous measurement and display of the
temperature in °C Celsius or °F Fahrenheit (according
to setting)
7.1.2 Service
variables
The service variables enable the user to retrieve information on the current status in the
FCU. The service variables are not calibrated.
7.1.2.1
Service variables "Flow"
Display
Description
120
Display of the averaged flow through the
ContminationSensor unit (Example 120 ml/min)
7.1.2.2
Service variables "Drive"
Display
Description
60
Shows the efficiency (1-100%) with which the LED
currently works in the FCU (Example 60 %).