8 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
98 / 120
BeWa MFU-15E_S 4391552c en-us web
Proceed as follows to install:
4.
Check the O-ring
(712)
for damage and replace it if
necessary.
5.
Insert the O-ring
(712)
into the connector.
6.
Use the screwdriver
= 16 x 2 to screw the protective
screen
(711)
into the connection in clockwise direction.
7.
Install the suction hose.
O
The assembly of the strainer is complete.