5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
54 / 120
BeWa MFU-15E_S 4391552c en-us web
Fig. 19:
Adjusting the feet 44°⇨ 0°
To adjust both feet from 44° to 0°, proceed as follows:
4.
Fully unscrew both screws counterclockwise with an
Allen key.
5.
Rotate the foot ≈ 22° inwards so that the bores in the
foot can be seen in the other threaded hole at the 0° po-
sition in the filter head.
6.
Rotate the two screws clockwise into the other threaded
holes (position 0°) and tighten them securely with a
3 Nm torque.
NOTICE! Ensure that the screws are located fully in-
side the threaded holes. If the screws protrude out of
the threaded hole, the position has not been chosen
correctly. Select the right position using the hole in
the foot.
O
The adjustment of the feet from 44° to 0° is complete.