5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
68 / 120
BeWa MFU-15E_S 4391552c en-us web
5.7 Attaching/connecting the suction/pressure hoses
(accessories)
The suction/pressure hoses from the filter unit
are matched to the filter unit. If you use different con-
nection hoses, take into account the pressure loss when con-
necting suction/pressure hoses.
The
IN/OUT
connection dimensions on the filter unit can be
NOTICE
High solid particle contamination in the fluid / at the bottom of
the tank
The pump is damaged / destroyed.
u
Do not suction the fluid directly at the bottom of the tank
where the sediment is.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom
of the tank.
Prevent aeration of the medium by fully immersing the lance
in the medium.
Ensure that the lance is always below the level of the oil dur-
ing operation.
Check the hoses for damage and brittleness. Replace dam-
aged or brittle hoses immediately. Doing so avoids leakages.
Put the hoses with the lance, without any tension and or twist,
into the corresponding tank. Put the hose with the lance into
the corresponding tank without any tension or twist. Secure
the hose so that it cannot fall out or float.
Check that no shut-off devices in the lines/hoses are ob-
structed. Make sure there is a depressurized outlet.
1