5.
During recirculation, continuously monitor the filling level
on the oil tank/container to be filled.
If the required filling quantity is reached, switch the filter
unit off at the main switch.
6.
Release the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
7.
Empty the contents of the pressure hose into the oil
tank/container.
8.
Empty the contents of the suction hose into the oil tank/
container.
9.
Secure the pressure hose at the quick coupling, see
moving/installing the quick coupling [
.
10.
Secure the piping and, if required, the hoses to the filter
unit, see
.
O
Recirculation with filtration/dewatering is complete.
NOTICE
Transport/storage after operation with dewatering
The filtration unit will be damaged by corrosion
u
Pump/flush the filter unit fully after operation with dewater-
ing.