EGPF Merchandisers
P/N 3143042_B
1-3
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
REMOVE SHEET METAL LIFTING BRACKETS
The brackets that were used as lifting points to move the case can now be removed from
the case ends.
Remove Bolts
LEVELING
Merchandisers must be installed level to ensure proper operation of the refrigeration
system and to ensure proper drainage of defrost water. When leveling merchandisers, use a
carpenter’s level. Leveling shims or wedges are provided with each merchandiser for use if
needed.
NOTE: BEGIN LINEUP LEVELING FROM THE HIGHEST POINT OF THE STORE FLOOR.
Shim Here
Shim Here
Rear of Case
Base Component
The front shipping rider can be positioned
at the front of the two end base uprights in
order to help square and align the base for
drilling to floor.
Place shims under the end bases if the floor
is not level. Use a 4 ft level to make sure the
case is level.
Placing shims at other locations will cause
uneven distribution of weight leading to
piping leaks, as well as sagging or wracked
doors.
Supports must be shimmed if not in full
contact with the floor.