FIELD INSTALLATION OF CONDENSING
UNIT
A mounting plate is provided on top of the case
with pilot holes that provide specific attachment
points for the condensing unit base. The mounting
plate is located above the next to last door on the
right, facing the case.
The condensate pan (if provided) is packed inside
the case and must also be installed and leveled on
top of the case, then hard-wired at the electrical
box.
Exact component location is not critical; however,
the components should be mounted in the
general locations shown to ensure that electrical
connections reach, and the condensate pan has
adequate air flow from the condenser. See location
example below.
Fasten Condensing Unit to Mounting Plate.
3141403
INSTRUCTION-ELEC WIRE
ROUTING EGPF-MT
FREEDOM - ELEC HARNESS ROUTING
WATER TUBING CONNECTED
TO PUMP MODULE LOCATED IN
BOTTOM OF THE CASE
SEE INSTRUCTION IN 3135558 - PUMP MODULE
B
D
Pump Module wire harness is
routed through
C
onduit and
connected to the
E
lectrical
B
ox
.
Harness is routed
to Fan Plenum
Sensor Wiring from bottom
is routed into Electrical Box.
Free Terminals of Fan
Harness.
Molex Terminal of
Fan Harness
Electrical Enclosure
Pump Module Electrical Harness
Water Tubing to Pump Module
located in bottom of the case
Evap. Pan Heater
Evap. Pan Heater Whip is connected to Elec.
Module Receptacle
Receptacle for Heater Pan
Connection
Field Electrical Connections in Enclosure
Pressure Switch and Temp Sensor
from Condensing Unit Connected to
Elec. Module through this port.
To Condensing Unit
Power Supply
Cover for Cutout in Upper
Back Foam Panel
Partial Top View
Detail B
Case Controller
Condensing Unit