P/N 3143042_B 1-7
EGPF Merchandisers
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
INSTALLING PUMP & COLLECTION PAN KIT
The bottom drain for defrost water from the evaporator coil of the case is connected to an
evacuation pump, which uses plastic drain tubing to pump the water to the condensate pan
on top of the case. See next page for part list assembly.
Evaporation pan must be installed level and plugged into electrical receptacle. The tubing
should be inspected through its entire length to ensure that it has not been cut, kinked,
obstructed, or damaged during shipping and installation.
Pump & Collection Pan Kit
(sits underneath case)
1.
2.
Steps:
1. Remove cover plates.
2. Connect case wire whip to pump.
EXPLODED VIEW
6
5
PART LIST - ASSEMBLY
ITEM
PART NUMBER
TITLE
QTY
1
3105147
PAN-STEAM ANTI JAM 2.50 HGT
1
2
3135560
LID ASSY-BLUE DIAMOND EGP-MT
1
3
3135494
SUPPORT-CONDENSATE PAN EGP
1
4
3135561
ENCLOSURE ASSY-BLUE DIAMOND EGP-MT
1
5
0460068
RIVET FLUSH BREAK 1/8 STL
4
6
0534121
SCREW-SM 8-18X5/8 PHIL HX HD
5
7*
0131401
TAPE-ADHESIVE TRANSFER
5 inches
Pump
Pan
GDF
3.
0
SH
EET
S
IZ
E
D
NOTES:
1. APPLICABLE STANDARDS / SPECIFICATIONS
ASME Y14.5M-1994, DIMENSIONS AND TOLERANCES
2. KEY PRODUCT CHARACTERISTICS PER EPR-0006 & IDENTIFIED WITH SYMBOL
3. MATERIAL- N/A
4. REF 3107767
K
SHEET 2 OF 2
3135561
C
ENCLOSURE ASSY-BLUE
DIAMOND EGP-MT
P/N
REV
THIRD
ANGLE
PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
R
CABLE ROUTING
SCALE 1.35:1
BLACK
WHITE
GREEN
Cable Routed to
Top Electrical
Enclosure
Ground Cable
FRONT VIEW
SCALE 1.35:1
2.00
TUBE-PVC CLEAR 0.250 ID X 0.500 OD
CUT THE PVC PIPE TO
THE SHOWN LENGTH
2.00
TUBE-PVC CLEAR 0.250 ID X 0.500 OD
CUT THE PVC PIPE TO
THE SHOWN LENGTH
CONNECTOR-3
WIRE
12-18AWG