STOCKING
Product should not be placed in lockers until
all refrigeration controls have been verified and
locker cabinets are at proper operating condi-
tions.
Discharge air slots (at rear of each compartment)
and return air slots (underside of each horizontal
door mullion must remain open at all times. Do
not allow products or packages to block this air
flow slots. Do not use unapproved accessories
that could hamper air system performance.
Keep doors closed as much as possible to prevent
coil frosting and high locker temperatures.
MAXIMUM LOCKER VOLUMES
Do not exceed 100 lbs per locker. Exceeding
the maximum weight load limits may cause
damage to the shelf or shelves, damage to the
lockers, product damage and potentially create
a hazardous condition for customers and staff.
WASTE OUTLET AND WATER SEAL
Water gravity drains from the internal evapora-
tor pan via an integral drain trap. Condensate
removal is via evaporation using the compressor
discharge loop in the condensate collection pan.
Care should be taken at start up to prime the in-
tegral trap to prevent air infiltration during initial
run down.
INSTALLING FDA/NSF REQUIRED
THERMOMETER
ONE THERMOMETER IS REQUIRED FOR EACH
LOCKER DOOR COMPARTMENT PER NSF.
Locker thermometers are to be installed in the
interior top portion of the locker cabinet. These
thermometers are necessary for food safety.
This thermometer may not be required or
provided in other countries. Check for local
code requirements.
This is an NSF-7 &
US FDA Food Code
Required
Thermometer
Hussmann P/N 0429971_C
10/2007
Double Stick Tape
Flexible Plastic
Fits in Price Tag
Moldings
•
•
•
©
Thermometer
—
Hussmann
Hussmann Corporation 12999 St. Charles Rock Road Bridgeton, MO 63044-2483
U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 www.hussmann.com
2013 Hussmann Corporation
Inside
End Panel
Return
Air Grille
Suggested Mounting Locations in
Multi-deck Merchandisers
Shelf Price Tag
Moulding
Suggested Mounting Locations
in Single Deck Glass Front
Merchandisers
-— Acrylic
Package Guard
Fading Out
Regularly check locker compartment temperatures! Do not
break the cold chain. Keep refrigerated products in cooler
of freezer before loading into locker. Medium temperature
refrigerated modules are designed for loading only
pre-chilled products. Low temperature refrigerated
modules are designed for loading only frozen products.
Содержание Smart Exchange
Страница 48: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 4 8 NOTES...
Страница 56: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 8...
Страница 58: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 10 NOTES...
Страница 68: ...P N 3110238_B 8 4 APPENDIX Sensor Resistance Pressure Sensor SENSOR REISTANCE AND PRESSURE...