![Hussmann Smart Exchange Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/hussmann/smart-exchange/smart-exchange_installation-and-operation-manual_2189330011.webp)
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
P/N 3110238_B
1-5
Smart Exchange Food Lockers
SHIPPING DAMAGE
Control kiosk and refrigerated modules should
be thoroughly examined for shipping damage
before and during unloading.
Refrigerated modules have been carefully inspected
at our factory. Any claim for loss or damage
must be made to the carrier. The carrier will
provide any necessary inspection reports and/
or claim forms.
Apparent Loss or Damage
If there is an obvious loss or damage, it must be
noted on the freight bill or express receipt and
signed by the carrier’s agent; otherwise, carrier
may refuse claim.
Concealed Loss or Damage
When loss or damage is not apparent until after
refrigerated modules are uncrated, retain all packing
materials and submit a written request to the
carrier for inspection, within 15 days.
SHIPPING SKID
Each refrigerated module and control kiosk
(module) is shipped on a skid to protect the
base and to make positioning easier.
Do not remove the shipping skid until the
refrigerated modules are near the final location.
The shipping skid is fastened to the refriger-
ated module’s base with bolts. Remove the
bolts in order to remove the skid. Once the
skid is removed, modules must be lifted —
NOT PUSHED— to reposition.
UNLOADING FROM TRUCK / TRAILER
Unless specifically arranged otherwise, it is
the customer’s responsibility to arrange the
off-loading, unpacking, and moving of the
locker assembly to the final site location.
Improper handling may cause damage when
unloading. A forklift is recommended. Pallet
jacks can also be helpful in moving a refriger-
ated module to its permanent location.
UNLOADING INDOOR REFRIGERATED
MODULES
Indoor refrigerated modules can be tilted over
on the compressor side in order to move the
refrigerated modules into the store if shipped
with a tilt-rider kit.
The refrigeration system
can not be started until after 24 hours after it has
been tilted over on its’ side. Damage to the
refrigeration system may result if the refrigerated
modules are started up sooner.
Use extreme caution when lifting or
moving refrigerated modules. Tall objects
may be prone to tip over. Always remain
at a safe distance to avoid severe injury or
death.
Do not start refrigeration until 24 hours
after condensing units were righted after
being tilted or tipped over.
Содержание Smart Exchange
Страница 48: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 4 8 NOTES...
Страница 56: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 8...
Страница 58: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 10 NOTES...
Страница 68: ...P N 3110238_B 8 4 APPENDIX Sensor Resistance Pressure Sensor SENSOR REISTANCE AND PRESSURE...