16
104 72 79-26
8. The height of the hook
The height is checked between the bobbin case and the case holder.
Check
The distance between the bobbin case and the case holder should be 0.5
+ 0.1
-0,05
mm.
The check is carried out at the tightest spot between the bobbin case and the case holder.
&KHFNDWWKHPDUNHGSRVLWLRQDFFRUGLQJWRÀJ
Adjustment
1. Loosen screw (A).
3XVKWKHEREELQFDVHGRZQZLWKDÀQJHU
3. Put a 0.6 mm feeler gauge between the bobbin case and the bobbin case holder.
Place it where the threading arrow is located on the bobbin case holder.
/LIWDZD\WKHÀQJHU$VSULQJLVSXVKLQJWKHKRRNXSZDUGVPDNHVXUHWKDWLWURWDWHVXSVRLWLVSRVLWLRQHG
against the feeler gauge.
5. Tighten the screw (A).
6. Re-check the setting, now with a 0.5 feeler gauge. It shall go in, but a small resistance shall be felt.
NOTE!
This setting affects:
11. The needle height
12. The timing of the hook and the needle
Check with distance gauge 412 38 85-01.
ÀJ
ÀJ
Settings
MM
!