6.2.9.1
Thermostat Connection
Remove the boiler casing, tilt the control
panel and connect the thermostat
to the 6 pole terminal board as indicated in
the boiler electrical diagram
(section
6.2.10)
after having removed the exi-
sting bridge (terminals 6-5).
The thermostat to be used must be
of a class conforming to the standard EN
60730.1 (clean electrical contact).
6.2.9.2
Remote control CR 63
connection (optionals)
The boiler is designed for connection to a
remote control unit CR 63 code 8092219
coupled to an optional expansion kit code
8092240.
The remote control unit allows for complete
remote control of the boiler, except release
of the boiler.
When the connection has been made the
boiler display will show the following messa-
ge:
Cr
.
For installation and use of the remote con-
trol, follow the instructions in the package.
6.2.9.3
External sensor connection
(optional)
The boiler is designed for connection to an
external temperature sensor, supplied on
request (code 8094101), which can auto-
matically regulate the temperature value of
the boiler output according to the external
temperature.
For installation, follow the instruction in the
package. It is possible to make corrections
to the values read by the drill acting on the
PAR 4
Page 22 of 34
NOTE: Any thermostat or external control unit must be installed by
an authorised person in accordance with AS 3000 - wiring rules.