Model
FORMAT DGT 30i and 30e Central Heating Boilers
Heat output -
Natural Gas @ 1.13 kPa -
ominal - 10.8 kW reduced.
29.4 kW N
Natural Gas @ 1.13 kPa -
MJ/h Nominal - 45.1 MJ/h reduced.
123.0
L P Gas @ 2.75 kPa - 29.4 kW Nominal - 11.8 kW reduced
L P Gas @ 2.75 kPa - 123.0 MJ/h Nominal - 49.1 MJ/h reduced.
Nominal (80-60°C)
Heat input
Supply voltage
240 Volts - 50 Hz
145 Watts
Adsorbed power consumption
C.H. setting range
20/80 °C
31 kg
NG
mm dia / LPG 0.85 mm dia
1.45
NG
/ LPG2.50 kPa
0.79 kPa
13 injectosr
3.0 Bar
6.1 litres
85 °C
10 litres
1.2 Bar
Water content boiler
Maximum water head
Maximum temperature
Capacity of the heating expansion vessel
Pressure of the heating expansion vessel
Weight when empty
Main burner nozzle
Quantity of injectors
Natural Gas / LP Gas injector diameter
Natural Gas / LP Gas test point pressure
6.1.3
TECHNICAL FEATURES
Page 14 of 34
IMPORTANT
INSTALLATION AND ALL SERVICING
MUST BE CARRIED OUT BY AN
AUTHORISED PERSON
NOT SUITABLE FOR USE AS A
POOL OR SPA HEATER
NOT SUITABLE FOR USE AS
A POOL OR SPA HEATER
Содержание sime 30e