033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 28 of 96
Note: As shown in the head assembly section, it is advised to mount the head onto
the neck, before placing the accelerometers in the head cavity.
To remove the accelerometers, the procedure described above must be performed
in the reverse order.
Alternative Instrumentation
The cavity in a Q6 dummy head is large enough to accept an array of angular
velocity sensors, type -01 or ARS-06 (flanged version) (Applied Technologies –
ATA Sensors). To mount these sensors, the use of an alternative accelerometer
mounting base is required (part No. 020-1014). On the standard head
accelerometer mounting base (020-1013A) the application of DTS-ARS sensors is
possible. For additional information on the mounting of these sensors, see
Section
3. Instrumentation and Figure 5
4.3
Neck
Construction
Table 7.
Neck assembly parts
Description
Part No.
Qty. in
Assembly
Neck Assembly Tested and Certified
033-2300
1
Neck Molded, pre-tested
033-2301
1
Neck cable assembly, pre-tested 033-2200
1
Nut
020-2204
1
Screw FHCS M3 x 8
5000116
2
The main part of the neck assembly consists of a rubber column, with bonded
metal interface plates attached to the top and bottom. The neck assembly has four
threaded inserts in the top surface which are used to mount the upper neck load
cell (Humanetics model IF-217 or IF-218) or its structural replacement onto the
neck. The upper neck plate has two cut-outs towards the rear to allow proper
routing of the upper neck load cell cables.