certification is the same as the initial bending direction experienced in the
test the dummy is being certified for (LHS or RHS).
4.
Attach the head form-neck system to the Part 572 pendulum. The side of the
head form should point in the direction of motion of the pendulum (see
).
5.
Install the potentiometers to the mounting interface and on the head form
central block. Mount the balance mass for the potentiometer on the other
side of the central block. This ensures that the inertial properties of the head
are symmetrical in the impact direction.
and orientation of the potentiometers.
6.
Insert the rod connecting the axes of the potentiometers and tighten the
screw on the bottom-most axis to secure the rod to the potentiometer. The
other end of the rod should be able to slide freely through the upper most
transducer axis. The rod must be protruding from both sides of the
transducers axes equal length.
7.
The minimum time interval to observe between tests on the neck is 30
minutes
.
Figure 30.
Q6 neck certification test set-up for lateral test