033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 27 of 96
Assembly and Disassembly
Disassembly
The head is attached to the neck though the load cell or the structural
replacement. To disassemble the head, first detach the load cell or its structural
replacement from the neck.
1.
First remove the head rear assembly by unscrewing the four button head cap
screws at the back of the head.
2.
The accelerometer array can be removed in order to provide access to the
screws in the upper neck load cell (or the load cell replacement).
3.
With the accelerometer array removed, the M5 SHCS screws that attach the load
cell to the neck can be reached through the top of the head.
4.
Remove the head and upper neck load cell or structural replacement from the
neck.
5.
Turn the head upside down, and remove the FHCS screws at the base of the
head.
Assembly
The head can be assembled to the dummy by reversing the order of the
disassembly.
Instrumentation
Standard Instrumentation
1.
To install the accelerometers, first remove the head rear assembly by
unscrewing the four M5 x 12 button head screws.
2.
Remove the head accelerometer mounting base (020-1013A), from the head
cavity, by unscrewing the three cap head screws.
3.
The uni-axial accelerometers must first be mounted onto a mounting block
I.AM or I.AD (see Figure 2).
4.
Bolt the mounting block onto head accelerometer base using the two socket
head cap screws supplied with the mount. Mount the interface inside the head
front assembly.
5.
Replace the head rear assembly and tighten the four bolts.
Содержание Q6
Страница 1: ...Q6 Advanced 6 year old child User Manual ...