033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 43 of 96
Figure 17
.
Lumbar spine assembly and abdomen
Instrumentation
Load Cell
A Humanetics IF-217 or IF-218 6-Axis Load cell may be mounted between the
lumbar spine and pelvis.
1.
To do so, first remove the upper torso from the lumbar spine by removing the
two M6 x 43 screws.
2.
Then unscrew the four M5 x 12 counter-sunk head screws attaching the
structural replacement to the pelvis. Remove the lumbar spine/structural
replacement assembly from the pelvis casting.
3.
Unscrew the four M5 x 12 screws to remove the structural replacement from
the lumbar spine.
4.
Now replace the structural replacement with the actual load cell and install the
four M5 x 12 cap head screws. The base plate of the load cell should be facing
down, and the cable exits at the rear of the dummy when the assembly is put
onto the pelvis casting.
5.
Mount the assembly onto the pelvis casting using four M5 x 12 countersunk
screws.
Содержание Q6