033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 36 of 96
2.
Use two SHCS M3 x 10 screws to attach the mounting block inside the cavity.
The longest side of the mounting base should be facing upward.
Load Cell
1.
To use the lower neck load cell (IF-217 or IF-218), remove the load cell
structural replacement (020-2007). If the neck is installed, remove this first
(four M5 x 10 button head cap screws).
2.
Note that there is a Neck torso interface plate (033-2308) between the load cell
structural replacement (020-2007) and the neck. Remove the load cell
structural replacement and the neck torso interface plate together by
unscrewing the four M5 x 12 socket head cap screws.
3.
Remove the neck torso interface plate (033-2308) from the load cell structural
replacement by unscrewing the four M5 x 10 countersunk screws.
4.
Install the load cell by reversing the procedure described above. First, attach
the neck torso interface plate (033-2308) to the load cell with the four
countersunk screws.
5.
Place the load cell on top of the thoracic spine (033-4401). The base plate
should be facing upward, and the cable exits should be at the rear, cables
leading downward. Fasten the load cell with the four socket head cap screws.
6.
Finally, assemble the neck back on the torso.
IR-TRACC
The thorax rib cage is equipped with an IR-TRACC displacement sensor that fits
into the cavity of the thoracic spine directly below the cavity for the
accelerometers.
provides the part list for the IR-TRACC attachment while
show the attachment parts for spine and rib side.
Table 9.
IR-RTRACC attachment: part list frontal impact configuration