033-9900 User Manual Q6 (Advanced 6 year old) Rev. M
©2016 Humanetics Innovative Solutions Inc.
©
Page 90 of 96
Figure 35.
Impact Location Point Lateral Thorax Certification
The impactor front surface should be just barely touching the suit while
the probe is hanging in its lowest position
Dummy’s X-axis should be perpendicular to impactor as close as possible.
3.
Make sure that the IR-TRACC is not mounted for frontal impact as the side
impact test can cause damage to the IR-TRACC when it in its set-up position
for frontal impacts.
4.
Measure and record the impact velocity with the speed vane on the probe.
5.
The minimum time interval to observe between tests on the thorax is 30
minutes.
Data Processing
1.
All data channels should be filtered at CFC600.
2.
Set the time zero at the 1 g deceleration level in the impactor signal (after
filtering with CFC600 software filter).
Содержание Q6