ULTRASOUND EQUIPMENT USER MANUAL

6

Form 1 Safety symbol table

NO.

Graphics, Symbols, Words

Name

Meaning

1

Warning

Warning

Used to indicate if you ignore it will result in serious

personal injury, death or actual damage to property.

2

Careful

Careful

Used to indicate if you ignore it will produce slight

personal injury or property damage.

3

Attention

Attention

Used to prompt the user installation, operation and

maintenance

information,

this

information

is

important, however, there is no danger, danger
warning not included in the note content.

Graphics, symbols, abbreviations

In the instrument(or in the manual), used in the graphics, symbols, abbreviations listed instructions are

shown in form 2, They are used to indicate when transportation, loading and unloading, and storage in

the assignments need to pay attention to, to ensure the safety of the instrument

Form 2 the Description of Graphics, symbols, abbreviations

NO.

Graphics, Symbols, Abbreviations

Name

Meaning

Identification of

Position

1

Power Ready

Connected (main power)

On the power

button

2

Power off

Off

main power

On the power

button

3

Power switch

Power switch position

By the power

switch

4

Intensity control

Adjust image brightness

Beside the display

5

Contrast control

Adjust image contrast

Beside the display

6

Driving direction

Open the control panel lock
hook

Before the box at

the top of the

7

B-type

Type B applied part

Operation panel

8

Adjust direction

Brightness, contrast, the

total gain, the direction in
which the focal point

Adjust knob

on/near

9

GAIN

Total gain

The total gain adjustment

knob

Beside the total

gain adjustment

knob

10

FOCUS

Focus point

The focus knob

Beside the focus

knob

11

+

Enlargement

Increasing/to increase

On the panel

Содержание MT128V

Страница 1: ...ULTRASOUND EQUIPMENT USER MANUAL 1 HUMAN FULL DIGITAL ULTRASONIC DIAGNOSTIC INSTRUMENT LED USER MANUAL MT128V...

Страница 2: ...curity Features 12 Chapter 2 Functions Technical Indexes and Configuration 13 2 1 Operating Environment 13 2 2 Main Functions 13 2 3 Main Technical Indexes 14 2 4 Configuration 14 Chapter 3 Operation...

Страница 3: ...ing gestational age 30 5 9 8 AC Abdominal long measuring gestational age 31 5 9 9 Gestational age data report page 32 5 10 Notes 32 5 11 Gender Notes 33 5 12 Body Mark Notes 33 5 13 Setting the Time 3...

Страница 4: ...ction 39 6 5 Insurance Tube Replaced 39 Chapter 7 Fault Checking and Ruled Out 40 7 1 Fault Checking Need Attention 40 7 2 Fault Checking and Ruled Out 40 Chapter 8 Transportation and Storage 41 8 1 T...

Страница 5: ...manufacturer can provide for a period of one year free warranty service Other artificial damage like user tear up the seals faulty operation etc the manufacture do not provide free maintenance servic...

Страница 6: ...ng and storage in the assignments need to pay attention to to ensure the safety of the instrument Form 2 the Description of Graphics symbols abbreviations NO Graphics Symbols Abbreviations Name Meanin...

Страница 7: ...e of the probe Package indicative mark On the packing cases are listed in form 3 packaging storage and transportation it is used to indicate when transportation loading and unloading and storage in th...

Страница 8: ...The instrument can t use with cardiac defibrillator and high frequency surgery or treatment equipment to prevent electric shock or damage to the instrument on patients 8 The instrument is forbidden t...

Страница 9: ...order to avoid possible electric shock risk Any instrument maintenance and upgrade must be authorized by the manufacturer training and service personnel 10 Sundry water cup etc are not permitted on t...

Страница 10: ...k or by image viewer has measurements of distance area circumference heart rate gestational weeks BPD GS CRL FL HC OFD TTD AC 8 measurement kinds and so on Chinese and English transformation pseudo co...

Страница 11: ...3 The probe driven by the high voltage will change the electric signal into ultrasonic vibration and the ultrasonic wave is transmitted into human body 4 The ultrasonic wave produces the reflection s...

Страница 12: ...sed in the injured part 1 5 Security features Safety features of the instruments are as follows 1 5 1 Prevent electric shock type type I 1 5 2 Shock proof of degree type B applied part 1 5 3 Applicati...

Страница 13: ...and English translation Transformation in both English and Chinese in interface Zoom Local x 2 0 magnification rate Dynamic range 0 120dB adjustable Frequency T35R60B convex array probe real time sca...

Страница 14: ...R60 frequency of 3 5 MHz Optional probe T65R13B type cavity probe 80 elements R13 frequency of 6 5 MHz Basic performance as below NO Name of technical indexes Type T35R60B convex array probe Type T65...

Страница 15: ...Figure The operation panel is as follows Figure 3 1 Control Panel 3 2 Key text graphics enter numbers or marks enter characters or marks Space Make notes including hospital name name and age of patie...

Страница 16: ...tance measurement Circumference area measurement Heart rate measurement Gestational weeks gestation measurement mode Escape from the measurement and note Time set click arrow keys to move the cursor S...

Страница 17: ...ight under M mode Magnifies image Partial image magnification Puncture guidance function Image memory Up Down Clear the measurement and the note Positive and negative image selection Chinese English t...

Страница 18: ...version Select probe Up and down flip Reset the unit GAIN Adjust the overall gain TGC Adjust the gain applied to the near field of the image TGC Adjust the gain applied to the far field of the image B...

Страница 19: ...the power needs to use extended patch panel please choose a product with the safety certification Attention 1 When unpacking and installation instrument to should take put down gently 2 Instruments u...

Страница 20: ...nd wire provide by the manufacturer which is in the packing box Make sure one end of the wire is connected with ground pole and the other end is connected with the ground The connection must be safe e...

Страница 21: ...he direction or position of the jamming equipment 3 Increase the distance between the interference equipment and the instrument Chapter 5 Method of Application 5 1 Caution When using the instrument pl...

Страница 22: ...sis should press the frozen button to make the probe to stop working 5 The probe s waterproof grade is IPX7 submerged probe for short periods of time shall not exceed 5 mm acoustic window position 6 U...

Страница 23: ...is a need to adjust the total gain the TGC display brightness and contrast to make the image s contrast and brightness and gain to a best state The interface is shown hospital name gender age year mo...

Страница 24: ...nly when it is in the magnification of 1 0 e Press The instrument works in M mode Note this function only works for 3 5MHz convex array probe in M mode 5 4 Image Magnification Selection When 3 5MHz co...

Страница 25: ...th when the cursor is fixed at the start point of the measurement in the M area under BM mode Measurement can not be carried on in the mode of annotation time setting and menu functions 5 7 Circumfere...

Страница 26: ...to confirm the start point of measurement d Press or touch the trackball to select the end point of measurement peak trough of the electrocardiogram e Press will display measured data on the right of...

Страница 27: ...e 5 9 1 BPD Bipartitely Diameter Press or to exit from other operations before measurement a Press will display the cursor b Press or touch the trackball to select the start point of the measurement c...

Страница 28: ...c Press to confirm the start point of the measurement d Press or touch the trackball to select the end point of the measurement and the gestational weeks expected date of confinement and the data of...

Страница 29: ...Step d and Step e to carry on another measurement g Press to exit from the gestational weeks measurement h Press to clear the measurement mark after exited from the measurement 5 9 4 FL Femur Length P...

Страница 30: ...s to confirm the center of the head circumference d Press or touch the trackball should put the fetus head image into the elliptical measurement cursor the edge of the ellipse cursor is more close to...

Страница 31: ...nal week measurement h After exited gestational week measurement press to clear the measurement mark of OFD 5 9 7 TTD Transverse Trunk Diameter a Press to highlight OFD on the right side cursor appear...

Страница 32: ...displayed AC XX X cm G A XX weeks EDD 20XX year XX XX month day G XXXX XXX g f Repeat step b to step e to carry on another measurement g Press the button to exit the gestational week measurement h Aft...

Страница 33: ...trace ball to move the cursor when noting characters in full screen Press to newline the cursor Press to transform between big and small letters the screen will reveal Caps at the right bottom of the...

Страница 34: ...y mark noting 5 13 Setting the Time Exit from other operations before setting Press will display the following information TIMESE MENU Year 20 Mouth Day Hours Minutes Week Hospital name Contains the y...

Страница 35: ...ation works in three section of focusing patterns c Press FO 2 3hows on right flank of the screen demonstrates This instrumentation works in two section of focusing patterns d Press FO 2 shows on righ...

Страница 36: ...with 4 patterns gamma correlation with 8 patterns COLOR 16 pseudo colors only effective with SVGA displayer MS scanning speed under M BM mode 8 type to choice only effective under M BM mode Press Esc...

Страница 37: ...fication Under frozen state press key a magnified box shows on the screen the image in the box is shown on the right as image multiplying factor of 2 0 press and other direction key or move the trackb...

Страница 38: ...g noting or setting press to select the language 5 28 U Disk image storage When scanning choice the image to freeze which need to be stored or after frozen bring up the permanent image insert the U di...

Страница 39: ...and the charge duration for each time is about 4 hours 6 2 3 If the instrument has not been used for a long time please place the instrument in the box 6 3 Probe Maintenance 6 3 1 The probes are vulne...

Страница 40: ...is not bright fan does not turn 1 Whether a power outage 2 The power cord plugs loose 3 Insurance tube fuse 1 Energized before using 2 Plug the power cord plug tightly 3 Replace the new insurance tub...

Страница 41: ...t Ambient temperature range 10 55 Range of relative humidity 80 or less Atmospheric pressure range 500hPa 1060hPa 8 3 Transportation The packing box is equipped with the simple quakeproof facility whi...

Отзывы: