11
8.
MAX TEMPERATURE ADJUSTMENT
1.
Turn the handle to the max temperature setting by turning the handle
anti-clockwise (fig 5). Measure the temperature with a thermometer.
2.
Remove the handle and brass stop ring if there is one, being very careful
not to turn the temperature spindle again.
3.
Using a small flat head screw driver (3mm), undo the plug screw located
inside the spindle which will allow you to access the calibration screw.
Water may leak from inside the cartridge now, this is normal.
4.
Using the same screw driver, locate the calibration screw inside the valve
and turn it clockwise to decrease the temperature and anti-clockwise to
increase the temperature. Please turn the screw driver in small
increments allowing time for the valve to adjust. Measure after each
adjustment until you reach the desired temperature. We recommend a
max of 47
°
C.
5.
Replace the handle or brass stop ring so that the stop lug is against the
cartridge stop lug and cannot move any further anti-clockwise. This sets
the max temperature.
6.
Turn the cartridge fully clockwise to the off position until it reaches the
stop. There should be no flow from the valve. If there is then the spindle
was most likely moved anti-clockwise during temperature adjustment and
the shut off position needs to be reset.
BRASS STOP RING UP AGAINST
CARTRIDGE STOP LUG AT THE
MAX TEMPERATURE SETTING
(FULLY CLOCKWISE)
REMOVE PLUG SCREW TO
ACCESS CALIBRATION SCREW
INSIDE BODY. BE CAREFUL NOT
TO TURN THE SPINDLE DURING
MAX TEMPERATURE SETTING
PROCEDURE
SPINDLE
FIG
5
FIG 6
Содержание 1/2 NPT
Страница 4: ...3 2 DIMENSIONS ALL DIMENSIONS ARE APPROXIMATE DIMENSIONS ARE BASED ON A TYPICAL PLATE OPTION NPT NPT...
Страница 6: ...5 5 COMPONENTS NPT NPT...
Страница 18: ...17 5 COMPONENTES NPT de NPT de...
Страница 30: ...29 5 PI CES Raccord NPT de po Raccord NPT de po...
Страница 38: ...37...