8
instead of turning the valve body around to match the pipework, the
cartridge can be taken out of the valve body, turned 180° and placed back
in the valve body. The Hot & Cold inlets will now match the incoming water.
When removing the cartridge, please undo the retaining nut and then pull
gently on the cartridge. There may be some residual water behind the
cartridge. Remove the cartridge from the valve body and turn it 180° so that
the positional lug on the cartridge lines up with the slot in the valve body.
Push the cartridge into the valve body making sure the lug is in the slot.
Replace the retaining nut being careful not to over tighten.
INSTALLATION:
1.
Remove the chrome sleeves from the shower valve body, and leave to
one side in a safe place.
2.
Determine the fixing position for the valve and make a recess in the wall
to house the valve. Please see the Dimension section for the depth of
recess required.
3.
Screw the shower valve body in position, using the mounting lugs that
are cast into the base of the body.
4.
Now the shower valve body is securely mounted onto the wall, make
sure the pipework is thoroughly flushed through to remove any debris