10
7.
FLOW SHUT OFF ADJUSTMENT
If the valve is not shutting of completely when in the fully off position, please
follow these steps:
1.
Remove the handle and/or the brass stop ring (if there is one with the
handle type).
2.
Loosely place the handle or brass stop ring on the spline and turn
clockwise. As soon as the water stops flowing remove the handle or brass
stop ring.
3.
Replace the handle or brass stop ring with the lug (fig 3 or fig 4) against
the cartridge lug so that the handle or brass stop cannot turn any further
clockwise. This sets the flow off position.
4.
If you need to you can now set the max temperature. Please see the next
section.
Integral Handle Stop Lug:
FIG 3
Brass bush in flow off position:
COLD ½”
BSP
FEMALE
INLET
BRASS STOP RING –
SOME
HANDLE TYPES HAVE A BRASS
STOP RING WHICH IS PLACED
OVER THE SPLINE AND MAKES
CONTACT WITH THE
CARTRIDGE STOP LUG
SETTING THE FLOW OFF
POSITION
STOP LUG
INTEGRAL HANDLE STOP LUG:
SOME HANDLES HAVE AN
INTEGRAL STOP LUG WHICH
MAKES CONTACT WITH THE
CARTRIDGE STOP LUG AND
SETS THE FLOW OFF POSITION
FIG 4