Step 5
Remove the chassis cover. For details, see
3.6-Removing the Chassis Cover
.
Step 6
Press the latches on both sides of the fan module to unlock it. See (1) in
.
Figure 3-11
Removing a fan module
Step 7
Lift the fan module slowly until it is completely out of the slot. See (2) in
Step 8
Place the removed fan module in an ESD bag.
----End
3.9 Installing a Fan Module
Step 1
Wear an ESD wrist strap. For details, see
12 Preventing Electrostatic Discharge
.
Step 2
Power off the server. For details, see
Step 3
Remove the power cables. For details, see
3.4 Removing Cables from a PSU
.
Step 4
Remove the server. For details, see
3.3 Removing the Server and Guide Rails
.
Step 5
Remove the chassis cover. For details, see
3.6-Removing the Chassis Cover
.
Step 6
Take a spare fan module out of its ESD bag.
Step 7
Insert the fan module along the guide rails into the slot until you hear a click. Check that the
fan cable connector is securely inserted into the mainboard connector. See
.
TaiShan 2280 V2 Server
User Guide
3 Basic Operations
Issue 01 (2019-07-01)
Copyright © Huawei Technologies Co., Ltd.
39