Parameter
Description
Value
<option>
Serial port direction
The value options of this parameter and
the value meanings vary according to the
server model. You are advised to run the
ipmcget -d serialdir
command to view
the value options.
For the server, the options are as follows:
–
0
: switch from PANEL COM to SYS
COM
–
1
: switch from PANEL COM to
iBMC COM
–
2
: switch from SOL COM to SYS
COM
–
3
: switch from SOL COM to iBMC
COM
To set the panel serial port as the iBMC
serial port, run the
ipmcset -d serialdir -
v 1
command.
l
To set the serial port by using a jumper, do as follows:
a.
Power off the server and remove the power cables.
b.
Place the jumper cap on COM_SW pins. For details about the jumper position, see
2.6 Mainboard and iBMC Card Connectors
.
c.
Connect the power cables and power on the server.
Step 2
Use a serial cable to connect the terminal serial port and the server serial port.
Step 3
Open HyperTerminal and set the following parameters:
l
Bits per second
: 115200
l
Data bits
: 8
l
Parity
: None
l
Stop bits
: 1
l
Flow control
: None
TaiShan 2280 V2 Server
User Guide
14 Common Operations
Issue 01 (2019-07-01)
Copyright © Huawei Technologies Co., Ltd.
150