SUN2000-(3.8KTL-11.4KTL)-USL0
User Manual
7 Operations on the Local FusionHome App
Issue 01 (2018-05-21)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
108
Parameter
Description
Value Range
Unlock optimizer
The optimizer needs to be
unlocked before inverter
replacement.
Disable
Enable
Night-time hibernation
The SUN2000 monitors PV
strings at night. If
Night-time hibernation
is
set to
Enable
, the
monitoring function of the
SUN2000 will hibernate at
night, reducing power
consumption.
Disable
Enable
TCP heartbeat interval
Set the TCP heartbeat
interval between the
management system and the
inverter. If it is set to 65535,
there is no heartbeat. If it is
set to 0, the heartbeat
interval is 3 minutes by
default.
[0, 65535]
Delay upgrade
This parameter is mainly
used in upgrade scenarios at
night when there is no
power output from the PV
strings or the dawn or dusk
when output is unstable.
Disable
Enable
LVRT
When the grid voltage is
abnormally low for a short
time, the SUN2000 cannot
disconnect from the power
grid immediately and has to
work for some time. This is
called low voltage
ride-through (LVRT).
Disable
Enable
Threshold for triggering
LVRT (V)
Specifies the threshold for
triggering LVRT.
[50%Vn, 92%Vn]
LVRT undervoltage
protection shield
Enables or disables the
undervoltage protection
shield during LVRT.
Disable
Enable
LVRT reactive power comp
factor
During LVRT, the
SUN2000 needs to generate
reactive power to support
the power grid. This
parameter specifies the
reactive power generated by
the SUN2000.
[0, 3]