SUN2000-(25KTL, 30KTL)-US
User Manual
5 Electrical Connections
Issue 03 (2017-04-01)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
57
If the neutral wire of the AC output power cable is connected and a 2 AWG cable is
required, expand the AC OUTPUT hole.
If cables are to be connected through a pipe, prepare a pipe by yourself. The
recommended pipe outer diameter is 42.47 mm (1.67 in.).
Procedure (Through a Pipe)
Step 1
Route the cables through the pipe and AC OUTPUT hole.
Step 2
Prepare OT terminals.
Figure 5-9
Stripping an AC output power cable
Wrap the wire crimping area with heat shrink tubing or PVC insulation tape. If heat shrink tubing is used,
wrap the cable with the heat shrink tubing and then crimp the OT terminal.
Step 3
Connect the SUN2000 AC output power cable to the AC terminal block and secure the cable
to a torque of 5 N·m.