SUN2000-(25KTL, 30KTL)-US
User Manual
5 Electrical Connections
Issue 03 (2017-04-01)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
50
Connect
ion
Method
Procedure
Connecti
on
Through
a Pipe
1.
Remove the waterproof connector from the bottom of the SUN2000.
2.
Route the cable through the pipe and then the cable hole.
3.
Secure the cable.
4.
Check that the cable is connected correctly and securely, and then secure
the pipe and seal the cable hole with firestop putty.
5.2 Opening the Maintenance Compartment Door
Prerequisites
Do not open the host panel of the inverter.
Before opening the maintenance compartment door, switch off the upstream DC input
circuit breaker and downstream AC output circuit breaker.
Do not leave unused screws in the chassis.
Procedure
Step 1
Loosen the two screws on the maintenance compartment door, as shown in
Figure 5-1
. Set the
screws aside for future use.