Installation Reference
64/65 >>
• Before powering on the equipment, ensure that:
- The RTN 900 has been powered on.
- The GE cable used for providing power over Ethernet has been installed.
• Power on the equipment within 24 hours of unpacking.
• During maintenance, the power-off time of the equipment must not be longer than 24 hours.
Caution
2. Check the system indicator on the RTN 310.
NOTE
In normal cases:
•The power over Ethernet indicator of the EG4P board on the RTN 900 is steady green, and the L/A3
indicator is steady green or blinks yellow. For the indicator status description, see the
OptiX RTN 900
IDU Hardware Description
.
•The system indicator on the RTN 310 is on. For the indicator status description, see the
Product
Description
.
System
indicator
1. Use the Web LCT to enable the PoE function for the interconnected port on the EG4P board of the RTN 900.
a. In the NE Explorer, select the desired NE from the Object Tree and choose
Configuration
>
Interface
Management
>
Ethernet Interface
from the Function Tree.
b. Click the
Advanced Attributes
tab.
c. Set
POE
to
Enabled
for the port that provides power over Ethernet to the RTN 310.
d. Click
Apply
.
RTN 900
RTN 310
Web LCT
Power over
Ethernet indicator
L/A3 indicator
Powering On the RTN 310 Working with the RTN 900
Powering On the RTN 310 Supplied by an Indoor PI
• Before powering on the equipment, ensure that:
- The GE cable used for providing power over Ethernet
and the PI power cable have been installed.
- The indoor PI works in PSE-PD mode. If the indoor PI is
powered on and works in FORCE mode, disconnect the
input power cable from the PI and push the power output
switch of the PI to the PSE-PD side.
• Power on the equipment within 24 hours of unpacking.
• During maintenance, the power-off time of the equipment
must not be longer than 24 hours.
Caution
NOTE
In normal cases, the DC IN and P&E OUT indicators are
steady green. For the indicator status description, see
the
Product Description
.
Switch on the power supply device connected to the PI.
Check the system indicator on the RTN 310.
System indicator
1
2
NOTE
In normal cases, the system indicator is on. For
the indicator status description, see the
Product Description
.
P&E ports (3/P1 and 4/P2) on the EG4P board
When a P&E port on the OptiX RTN 900 is connected to a
device other than OptiX RTN 300, the PoE function must be
disabled. Otherwise, the peer device may be damaged.
P&E port
Powering On the RTN 310 Supplied by an Outdoor PI
Check the system indicator on the RTN 310.
System indicator
2
NOTE
In normal cases, the system indicator is on.
For the indicator status description, see the
Product Description
.
PSE-PD
Power Output Mode
Before powering on the equipment, ensure that:
•The P&E cable and the PI power cable are installed.
•DIP switches are set correctly, and the DIP switch for setting the
PoE mode for the used P&E port is turned to the PSE-PD side.
After setting the DIP switches, switch off the power supply. After
waiting for 6 seconds, switch on the power supply again.
• Power on the equipment within 24 hours of unpacking.
• During maintenance, the power-off time of the equipment
cannot be longer than 24 hours.
Caution
NOTE
In normal conditions, POWER and P&E OUT indicators are on
(green). For a description of indicator states, see the PI
installation guide.
1
POWER
P&E OUT
Switch on the power supply device connected to the PI.