Step 2
Obtain disk logs by following instructions in
5.7.3 One-Click Log Collection
and contact
Huawei technical support.
----End
The service life exceeds the threshold.
Step 1
Check whether the value of
percentage used
in the SMART information exceeds 100%, if the
value is greater than or equal to 100%, stop using the disk and back up data immediately.
Otherwise, go to
Step 2
Collect disk log information. For details, see
5.7.3 One-Click Log Collection
. Contact
Huawei technical support.
----End
The temperature exceeds the threshold.
Step 1
Check that the server where the disk resides provides proper cooling. If the server reports no
temperature alarm and the fan modules are operating properly, go to
Step 2
Check that the server where the disk resides provides proper cooling. If the server reports no
temperature alarm and the fan modules are operating properly, go to
Step 3
Obtain disk logs by following instructions in
5.7.3 One-Click Log Collection
and contact
Huawei technical support.
----End
l
An internal error downgrades the NVM subsystem reliability.
l
The medium is read-only.
l
Device backup failed.
Step 1
Obtain disk logs by following instructions in
5.7.3 One-Click Log Collection
and contact
Huawei technical support.
----End
5.11 Indicator Status Descriptions
5.11.1 ES3000 SSD Disk Indicator State Descriptions
Table 5-2
ES3000 SSD disk indicator state descriptions
Green Indicator
Yellow Indicator
State Description
Off
Off
The NVMe SSD disk cannot
be detected.
On
Off
The NVMe SSD disk is
detected and working
properly.
2 Hz
Off
Data access to the NVMe
SSD disk is in progress.
ES3000 V3 NVMe PCIe SSD
User Guide
5 Maintenance and Upgrade
Issue 20 (2019-02-27)
Copyright © Huawei Technologies Co., Ltd.
85