Make certain that the field installed drain valve is completely closed. 

 

Open the shut-off valve in the cold water supply line. 

 

Open the hot water faucets to allow air to vent from the heater and piping. 

 

Allow sufficient time for the heater to completely fill with water. 

G. SCALDING 

 
This heater can deliver scalding water. Be careful whenever using hot water to avoid 
scalding injury. Certain appliances, such as dishwashers and automatic clothes washers 
may require increased water temperature. By setting the thermostat on this heater to 
obtain the increased water temperature required by these appliances, you may create 
the potential for scald injury. 
 
To protect against injury, you should install a mixing valve in the water system. This 
valve will reduce point of discharge temperature by mixing cold and hot water in branch 
supply lines. Such valves are available from your local plumbing supplier. 
 
Table 3 details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the 
safest water temperature for your applications. 
 

 

A temperature limiting or mixing valve is recommended in installations servicing disabled or elderly persons, or children. Take extreme 
caution to avoid scalding when temperature limiting or mixing valves are not used. 
 

Table 3 

APPROXIMATE TIME / TEMPERATURE RELATIONSHIPS IN SCALDS 

120

o

More than 5 minutes 

125

o

1 ½ to 2 minutes 

130

o

About 30 seconds 

135

o

About 10 seconds 

140

o

Less than 5 seconds 

145

o

Less than 3 seconds 

150

o

About 1 ½ seconds 

155

o

About 1 second 

Содержание EVR 040

Страница 1: ...nia to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in lit...

Страница 2: ...ire marshal chief of a fire prevention bureau labor department or health department building official or electrical inspector or others having statutory authority In some circumstances the property ow...

Страница 3: ...ORMANCE RATINGS 6 C LOCATING THE WATER HEATER 6 PART 3 HEATER PIPING 8 A PLUMBING 8 B THERMAL EXPANSION 8 C CONDENSATION 8 D INSULATION BLANKETS 8 E TEMPERATURE AND PRESSURE RELIEF VALVE 9 F FILLING T...

Страница 4: ...causing a fire and or explosion or the release of mold bacteria or other harmful particulates into the air Operating a previously submerged water heater could result in property damage severe persona...

Страница 5: ...er containing chlorine in excess of 100 ppm Hardness 7 grains Chloride levels 100 ppm pH levels 6 8 TDS 2000 ppm Sodium 20 mGL Failure of electric elements due to lime scale build up on the heating su...

Страница 6: ...ns See Table 2 for a Listing of Available Elements ELEMENTS AND THERMOSTATS AVAILABLE WATTAGE VOLTAGE FULL LOAD CURRENT IN AMPS Single Phase 2 3 000 240 13 4 500 19 Table 2 Listing of Elements and Cor...

Страница 7: ...evere personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to the piping system as possible 3 Check are...

Страница 8: ...n exceed the safety setting of the relief valve causing it to operate during each heating cycle This rapid and repeated expansion and contraction of components in the system can cause premature failur...

Страница 9: ...utlet and run to a safe place of disposal Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge Discharge line mus...

Страница 10: ...hould install a mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from your local plu...

Страница 11: ...maximum possible input allowable see Table 2 for listing of inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the w...

Страница 12: ...he wiring connections PART 5 INSTALLATION CHECKLIST WATER HEATER LOCATION YES NO Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Pro...

Страница 13: ...an and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal injury or death B THERMOSTAT ADJUSTMENT AND ECO...

Страница 14: ...ock STEP 2 Run hot water at a faucet in the system When it runs cold shut off the faucet Then shut off water at the main cold water inlet or if possible valve off the water heater from the system Drai...

Страница 15: ...iently over its service life The Owner User may perform the maintenance activities described below Monthly Every two weeks in hard water locations It is recommended that a few quarts of water be drain...

Страница 16: ...ected to the valve directing the flow of hot water from the valve to a proper place of disposal Replacement of the valve is required if no water flows when the lever is operated Turn the water heater...

Страница 17: ...2 Damaged seal ring washer 3 Gasket around heating element s 1 Tighten hex nut union fitting 2 Replace seal rings as required 3 Inspect and replace gasket if necessary Leaking Temperature and Pressur...

Страница 18: ...18 Figure 7 Parts Blowout...

Страница 19: ...19 NOTES...

Страница 20: ...s Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer ha...

Страница 21: ...reach of warranty D If government regulations industry certification or similar standards require the replacement water heater or part s to have features not found in the defective water heater or par...

Страница 22: ...s purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of your original receipt complete model and serial numbers and the date of installation of your...

Отзывы: