NOTE: REPEAT STEPS 3 

– 6 AS NECESSARY FOR MULTIPLE ELEMENTS

 

 

STEP #6 

– 

Open the main cold water inlet. If the water heater has been isolated from the system, open the valves. Refill the tank with 

cold water. Open a hot water faucet high in the system to bleed any air pressure from the system. Water will flow freely when air is 
completely bled. 
 

 

When filling the water heater, open a hot water tap to release air in the tank and piping. The tank must be full of water before the heater 
is turned on. Failure to ensure the water heater is full before turning it on will result in damage to the water heater, and could result in 
property damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty. 

 
STEP #7 

– 

Pressure check the tank for leaks around element. If no leaks are found, connect wires from the element to the thermostat. 

 

STEP #8 - 

Turn power back on to the water heater.

 

 

 

Failure to refill the tank before restoring power to the water heater will result in damage to the heating elements and property damage. 
Such damages ARE NOT covered by warranty. 

PART 7 – MAINTENANCE 

MAINTENANCE CONSIDERATIONS 

 

To avoid electric shock, disconnect electrical supply before performing maintenance. 

 

To avoid severe burns, allow heater to cool before performing maintenance. 

 
NOTE: 

In addition to the routine maintenance detailed in this manual, this water heater should be inspected annually by a qualified 

service technician to assure that all the equipment is operating safely and efficiently. The owner should make necessary arrangements 
with a qualified heating contractor for periodic maintenance of the heater. Installer must also inform the owner that lack of proper care 
and maintenance may result in a hazardous condition, premature heater failure, and void the warranty. 
 
Routine preventative maintenance ensures the water heater operates safely and efficiently over its service life. 

The Owner/User

 may 

perform the maintenance activities described below. 
 

Monthly (Every two weeks in hard water locations) 

It is recommended that a few quarts of water be drained from the heater. This will flush sediment deposits from the bottom of the heater 
and lengthen the heater’s service life. Turn off power to the heater during flushing operation, so the elements will not be damaged. 
  

 

Failure to shut off power to the heater when draining may damage the heating elements. Operating a partially filled/empty water heater 
could lead to damage from “dry-firing”. Failures due to such damage are NOT covered by warranty. 
 
To flush the tank, attach a hose to the field installed drain valve in the cold water supply line. Close supply line shut-off valve. Open 
drain line valve and hot water faucet(s) to vent heater while draining. Direct the flow of water to a drain or bucket where it will not cause 
damage. 
 

 

Water drained from the water heater may be scalding hot. Take care to avoid scalding. Wear gloves and safety glasses, and direct 
water to a safe drainage location. It is recommended to turn power off to the water heater and run the water at a hot faucet until it cools 
BEFORE draining water from the heater. Failure to comply with this warning could result in substantial property damage, severe 
personal injury, or death due to scalds.

 

 
After flushing until water runs clear, operation is complete. Close drain valve and reopen supply line shut-off valve. Make certain that 
heater is completely full of water before restoring power to the heater. 
 

Periodically (At least twice a year) 

Check around the water heater and related plumbing for leaks. If the combination temperature and pressure relief valve discharges 
periodically, or water is leaking from around the heating elements, there may be a problem with your water system. DO NOT ATTEMPT 
TO REPAIR LEAKS YOURSELF! Contact a qualified service contractor for assistance. 
 
Check the area around the water heater for flammable liquids or combustible materials. If any are found, remove from the area. 
 

Содержание EVR 040

Страница 1: ...nia to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in lit...

Страница 2: ...ire marshal chief of a fire prevention bureau labor department or health department building official or electrical inspector or others having statutory authority In some circumstances the property ow...

Страница 3: ...ORMANCE RATINGS 6 C LOCATING THE WATER HEATER 6 PART 3 HEATER PIPING 8 A PLUMBING 8 B THERMAL EXPANSION 8 C CONDENSATION 8 D INSULATION BLANKETS 8 E TEMPERATURE AND PRESSURE RELIEF VALVE 9 F FILLING T...

Страница 4: ...causing a fire and or explosion or the release of mold bacteria or other harmful particulates into the air Operating a previously submerged water heater could result in property damage severe persona...

Страница 5: ...er containing chlorine in excess of 100 ppm Hardness 7 grains Chloride levels 100 ppm pH levels 6 8 TDS 2000 ppm Sodium 20 mGL Failure of electric elements due to lime scale build up on the heating su...

Страница 6: ...ns See Table 2 for a Listing of Available Elements ELEMENTS AND THERMOSTATS AVAILABLE WATTAGE VOLTAGE FULL LOAD CURRENT IN AMPS Single Phase 2 3 000 240 13 4 500 19 Table 2 Listing of Elements and Cor...

Страница 7: ...evere personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to the piping system as possible 3 Check are...

Страница 8: ...n exceed the safety setting of the relief valve causing it to operate during each heating cycle This rapid and repeated expansion and contraction of components in the system can cause premature failur...

Страница 9: ...utlet and run to a safe place of disposal Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge Discharge line mus...

Страница 10: ...hould install a mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from your local plu...

Страница 11: ...maximum possible input allowable see Table 2 for listing of inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the w...

Страница 12: ...he wiring connections PART 5 INSTALLATION CHECKLIST WATER HEATER LOCATION YES NO Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Pro...

Страница 13: ...an and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal injury or death B THERMOSTAT ADJUSTMENT AND ECO...

Страница 14: ...ock STEP 2 Run hot water at a faucet in the system When it runs cold shut off the faucet Then shut off water at the main cold water inlet or if possible valve off the water heater from the system Drai...

Страница 15: ...iently over its service life The Owner User may perform the maintenance activities described below Monthly Every two weeks in hard water locations It is recommended that a few quarts of water be drain...

Страница 16: ...ected to the valve directing the flow of hot water from the valve to a proper place of disposal Replacement of the valve is required if no water flows when the lever is operated Turn the water heater...

Страница 17: ...2 Damaged seal ring washer 3 Gasket around heating element s 1 Tighten hex nut union fitting 2 Replace seal rings as required 3 Inspect and replace gasket if necessary Leaking Temperature and Pressur...

Страница 18: ...18 Figure 7 Parts Blowout...

Страница 19: ...19 NOTES...

Страница 20: ...s Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer ha...

Страница 21: ...reach of warranty D If government regulations industry certification or similar standards require the replacement water heater or part s to have features not found in the defective water heater or par...

Страница 22: ...s purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of your original receipt complete model and serial numbers and the date of installation of your...

Отзывы: