background image

 

PART 1 – GENERAL SAFETY INFORMATION 

A. PRECAUTIONS 

This water heater is approved 

for indoor installations only. Clearance to combustible materials: 0” top, bottom, sides and back. Heater 

must have room for service: 

24” front and 6” sides are minimum recommended service clearances. (A combustible door or removable 

panel is acceptable front clearance.) This water heater has been approved for closet installation, and installation on combustible 
flooring. Do not install this water heater directly on carpeting. 
 

 

INSTALLER 

– 

Read all instructions in this manual before installing. Perform steps in the order given. 

USER 

– 

This manual is for use only by a qualified heating installer/service technician. Have this water heater serviced/inspected by a 

qualified service technician annually.

 

FAILURE  TO  ADHERE  TO  THE  GUIDELINES  ON  THIS  PAGE  AND  HAVE  THIS  WATER  HEATER  SERVICED/INSPECTED 
ANNUALLY CAN RESULT IN SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH. 

 

NOTE:

 When inquiring about service or troubleshooting, reference the model and serial numbers from the boiler rating label. 

 

NOTE:

 If the heater is exposed to the following, do not operate until all corrective steps have been made by a qualified serviceman: 

 

FIRE  

 

DAMAGE  

 

WATER 

Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. 
 

 

DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN SUBMERGED IN WATER.

 Immediately call a qualified service 

technician. The water heater MUST BE replaced if it has been submerged. Attempting to operate a water heater that has been 
submerged could create numerous harmful conditions, such as a potential gas leakage causing a fire and/or explosion, or the release 
of mold, bacteria, or other harmful particulates into the air. Operating a previously submerged water heater could result in property 
damage, severe personal injury, or death. 
 

NOTE:

 Water heater damage due to flood or submersion is considered an Act of God, and IS NOT covered under product warranty. 

 

 

Be sure to disconnect electrical power before performing service. Failure to do so could result in an electrical shock, property damage, 
serious personal injury, or death. 
 

 

This water heater is not designed or intended for use in space heating applications. Failure of a water heater due to unapproved use IS 
NOT covered by the warranty. 

B. WHEN SERVICING THE WATER HEATING SYSTEM 

 

To avoid electric shock, disconnect electrical supply before performing maintenance. 

 

To avoid severe burns, allow heater to cool before servicing. 

C. HEATER WATER 

 

Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the system may 
be damaged. This can result in substantial property damage. 

 

Do not use “homemade cures” or “heater patent medicines”. Damage to heater, substantial property damage, and/or serious 
personal injury may result. 

D. INSTALLATIONS IN THE STATE OF CALIFORNIA 

 

California Law requires that residential water heaters must be braced, anchored, or strapped to resist falling or horizontal displacement 
due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing 
instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814, or you may call 916-324-5315, or 
ask a water heater dealer. 
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the 
local building jurisdiction for acceptable bracing procedures. 

Содержание EVR 040

Страница 1: ...nia to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in lit...

Страница 2: ...ire marshal chief of a fire prevention bureau labor department or health department building official or electrical inspector or others having statutory authority In some circumstances the property ow...

Страница 3: ...ORMANCE RATINGS 6 C LOCATING THE WATER HEATER 6 PART 3 HEATER PIPING 8 A PLUMBING 8 B THERMAL EXPANSION 8 C CONDENSATION 8 D INSULATION BLANKETS 8 E TEMPERATURE AND PRESSURE RELIEF VALVE 9 F FILLING T...

Страница 4: ...causing a fire and or explosion or the release of mold bacteria or other harmful particulates into the air Operating a previously submerged water heater could result in property damage severe persona...

Страница 5: ...er containing chlorine in excess of 100 ppm Hardness 7 grains Chloride levels 100 ppm pH levels 6 8 TDS 2000 ppm Sodium 20 mGL Failure of electric elements due to lime scale build up on the heating su...

Страница 6: ...ns See Table 2 for a Listing of Available Elements ELEMENTS AND THERMOSTATS AVAILABLE WATTAGE VOLTAGE FULL LOAD CURRENT IN AMPS Single Phase 2 3 000 240 13 4 500 19 Table 2 Listing of Elements and Cor...

Страница 7: ...evere personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to the piping system as possible 3 Check are...

Страница 8: ...n exceed the safety setting of the relief valve causing it to operate during each heating cycle This rapid and repeated expansion and contraction of components in the system can cause premature failur...

Страница 9: ...utlet and run to a safe place of disposal Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge Discharge line mus...

Страница 10: ...hould install a mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from your local plu...

Страница 11: ...maximum possible input allowable see Table 2 for listing of inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the w...

Страница 12: ...he wiring connections PART 5 INSTALLATION CHECKLIST WATER HEATER LOCATION YES NO Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Pro...

Страница 13: ...an and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal injury or death B THERMOSTAT ADJUSTMENT AND ECO...

Страница 14: ...ock STEP 2 Run hot water at a faucet in the system When it runs cold shut off the faucet Then shut off water at the main cold water inlet or if possible valve off the water heater from the system Drai...

Страница 15: ...iently over its service life The Owner User may perform the maintenance activities described below Monthly Every two weeks in hard water locations It is recommended that a few quarts of water be drain...

Страница 16: ...ected to the valve directing the flow of hot water from the valve to a proper place of disposal Replacement of the valve is required if no water flows when the lever is operated Turn the water heater...

Страница 17: ...2 Damaged seal ring washer 3 Gasket around heating element s 1 Tighten hex nut union fitting 2 Replace seal rings as required 3 Inspect and replace gasket if necessary Leaking Temperature and Pressur...

Страница 18: ...18 Figure 7 Parts Blowout...

Страница 19: ...19 NOTES...

Страница 20: ...s Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer ha...

Страница 21: ...reach of warranty D If government regulations industry certification or similar standards require the replacement water heater or part s to have features not found in the defective water heater or par...

Страница 22: ...s purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of your original receipt complete model and serial numbers and the date of installation of your...