FOR THE INSTALLER 

 
This water heater must be installed by qualified and licensed personnel. The installer should be guided by the instructions furnished 
with the water heater, and with local codes and utility company requirements. 
 

INSTALLATIONS MUST COMPLY WITH: 

Local, state, provincial, and national codes, laws, regulations and ordinances. 
 
The latest version of the 

National Electrical Code, NFPA No. 70

TABLE OF CONTENTS

 

PART 1 

– GENERAL SAFETY INFORMATION .......................................................................................................................... 4

 

A. PRECAUTIONS ................................................................................................................................................................................................ 4

 

B. WHEN SERVICING THE WATER HEATING SYSTEM .................................................................................................................................... 4

 

C. HEATER WATER ............................................................................................................................................................................................. 4

 

D. INSTALLATIONS IN THE STATE OF CALIFORNIA ......................................................................................................................................... 4

 

E. WATER CHEMISTRY ....................................................................................................................................................................................... 5

 

PART 2 

– PREPARE THE WATER HEATER ............................................................................................................................. 5

 

A. WHAT’S IN THE BOX ....................................................................................................................................................................................... 5

 

B. SPECIFICATIONS AND PERFORMANCE RATINGS ....................................................................................................................................... 6

 

C. LOCATING THE WATER HEATER .................................................................................................................................................................. 6

 

PART 3 

– HEATER PIPING ......................................................................................................................................................... 8

 

A. PLUMBING ....................................................................................................................................................................................................... 8

 

B. THERMAL EXPANSION ................................................................................................................................................................................... 8

 

C. CONDENSATION ............................................................................................................................................................................................. 8

 

D. INSULATION BLANKETS................................................................................................................................................................................. 8

 

E. TEMPERATURE AND PRESSURE RELIEF VALVE ........................................................................................................................................ 9

 

F. FILLING THE HEATER ..................................................................................................................................................................................... 9

 

G. SCALDING ..................................................................................................................................................................................................... 10

 

H. INSTALLATION DIAGRAMS .......................................................................................................................................................................... 11

 

PART 4 

– HEATER WIRING ...................................................................................................................................................... 11

 

PART 5 

– INSTALLATION CHECKLIST ................................................................................................................................... 12

 

PART 6 

– OPERATING THE HEATER...................................................................................................................................... 13

 

A. COMBINATION THERMOSTAT AND HIGH LIMIT CONTROL (ECO) ............................................................................................................ 13

 

B. THERMOSTAT ADJUSTMENT AND ECO RESET ......................................................................................................................................... 13

 

C. HEATING ELEMENT REPLACEMENT PROCEDURE ................................................................................................................................... 14

 

PART 7 

– MAINTENANCE ........................................................................................................................................................ 15

 

PART 8 

– TROUBLESHOOTING .............................................................................................................................................. 16

 

NOTES ................................................................................................................................................................................................................... 19

 

HTP CUSTOMER INSTALLATION RECORD FORM ............................................................................................................................................. 20

 

Residential Limited Warranty .................................................................................................................................................................................. 21

 

 

 

This manual must only be used by a qualified heating installer/service technician. Read all instructions in this manual before installing. 
Perform steps in the order given. Failure to comply could result in substantial property damage, severe personal injury, or death. 

Содержание EVR 040

Страница 1: ...nia to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in lit...

Страница 2: ...ire marshal chief of a fire prevention bureau labor department or health department building official or electrical inspector or others having statutory authority In some circumstances the property ow...

Страница 3: ...ORMANCE RATINGS 6 C LOCATING THE WATER HEATER 6 PART 3 HEATER PIPING 8 A PLUMBING 8 B THERMAL EXPANSION 8 C CONDENSATION 8 D INSULATION BLANKETS 8 E TEMPERATURE AND PRESSURE RELIEF VALVE 9 F FILLING T...

Страница 4: ...causing a fire and or explosion or the release of mold bacteria or other harmful particulates into the air Operating a previously submerged water heater could result in property damage severe persona...

Страница 5: ...er containing chlorine in excess of 100 ppm Hardness 7 grains Chloride levels 100 ppm pH levels 6 8 TDS 2000 ppm Sodium 20 mGL Failure of electric elements due to lime scale build up on the heating su...

Страница 6: ...ns See Table 2 for a Listing of Available Elements ELEMENTS AND THERMOSTATS AVAILABLE WATTAGE VOLTAGE FULL LOAD CURRENT IN AMPS Single Phase 2 3 000 240 13 4 500 19 Table 2 Listing of Elements and Cor...

Страница 7: ...evere personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to the piping system as possible 3 Check are...

Страница 8: ...n exceed the safety setting of the relief valve causing it to operate during each heating cycle This rapid and repeated expansion and contraction of components in the system can cause premature failur...

Страница 9: ...utlet and run to a safe place of disposal Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge Discharge line mus...

Страница 10: ...hould install a mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from your local plu...

Страница 11: ...maximum possible input allowable see Table 2 for listing of inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the w...

Страница 12: ...he wiring connections PART 5 INSTALLATION CHECKLIST WATER HEATER LOCATION YES NO Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Pro...

Страница 13: ...an and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal injury or death B THERMOSTAT ADJUSTMENT AND ECO...

Страница 14: ...ock STEP 2 Run hot water at a faucet in the system When it runs cold shut off the faucet Then shut off water at the main cold water inlet or if possible valve off the water heater from the system Drai...

Страница 15: ...iently over its service life The Owner User may perform the maintenance activities described below Monthly Every two weeks in hard water locations It is recommended that a few quarts of water be drain...

Страница 16: ...ected to the valve directing the flow of hot water from the valve to a proper place of disposal Replacement of the valve is required if no water flows when the lever is operated Turn the water heater...

Страница 17: ...2 Damaged seal ring washer 3 Gasket around heating element s 1 Tighten hex nut union fitting 2 Replace seal rings as required 3 Inspect and replace gasket if necessary Leaking Temperature and Pressur...

Страница 18: ...18 Figure 7 Parts Blowout...

Страница 19: ...19 NOTES...

Страница 20: ...s Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer ha...

Страница 21: ...reach of warranty D If government regulations industry certification or similar standards require the replacement water heater or part s to have features not found in the defective water heater or par...

Страница 22: ...s purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of your original receipt complete model and serial numbers and the date of installation of your...

Отзывы: