HTP EVR 040 Скачать руководство пользователя страница 9

 

 

If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully 
followed. 
 
In addition, pay careful attention to the following so as not to restrict the proper function and operation of the water heater: 

 

Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of the 
insulation blanket. 

 

Do not apply insulation to the top of the water heater. This could interfere with the safe operation of the electrical junction box. 

 

Do not cover the jacket access panel(s) to the thermostat(s) and heating element(s), or temperature and pressure relief valve. 

 

Inspect the insulation blanket frequently. 

Failure to follow these instructions could result in substantial property damage, severe personal injury, or death. 

E. TEMPERATURE AND PRESSURE RELIEF VALVE 

NOTE: 

For protection against excessive pressures and temperatures in this water heater, install temperature and pressure protective 

equipment as required by local codes, but not less than a combination T&P valve meeting the requirements for 

Relief Valves and 

Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22B / CSA 4.4-M99

, by a nationally recognized testing 

laboratory that maintains periodic inspection of production of listed equipment and materials. This valve must be marked with a 
maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the T&P valve into the opening 
provided and marked for this purpose on the water heater so that discharge water from the valve will not come in contact with any live 
electrical parts. 
 

 

To avoid water damage or scalding due to relief valve operation: 

 

Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line in a 
manner that will prevent possibility of severe burns or property damage should the relief valve discharge. 

 

Discharge line must be as short as possible and the same size as the valve discharge connection throughout its entire length. 

 

Discharge line must pitch downward from the valve and ter

minate at least 6” above the floor drain, making discharge clearly 

visible. 

 

The discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375

o

F or greater. 

 

Do not pipe discharge to any location where freezing could occur. 

 

No shutoff valve may be installed between the relief valve and heater or in the discharge line. Do not plug or place any 
obstruction in the discharge line. 

 

Test the operation of the relief valve after filling and pressurizing the system by lifting the lever. Make sure the valve 
discharges freely. If the valve fails to operate correctly, immediately replace with a new properly rated relief valve. 

 

Test T&P valve at least once annually to ensure the waterway is clear. If valve does not operate, turn th

e heater “off” 

and call 

a plumber immediately.

 

 

Take care whenever operating relief valve to avoid scalding injury or property damage. 

FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION, 
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH. 

 

 

Do not thread a cap or plug into the relief valve under any circumstances! Explosion and property damage, serious injury, or death may 
result. 

F. FILLING THE HEATER 

 

When filling the water heater, open a hot water tap to release air in the tank and piping. The tank must be full of water before the heater 
is turned on. Failure to ensure the water heater is full before turning it on will result in damage to the water heater, and could result in 
property damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty. 

Содержание EVR 040

Страница 1: ...nia to cause cancer birth defects or other reproductive harm NOTICE HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in lit...

Страница 2: ...ire marshal chief of a fire prevention bureau labor department or health department building official or electrical inspector or others having statutory authority In some circumstances the property ow...

Страница 3: ...ORMANCE RATINGS 6 C LOCATING THE WATER HEATER 6 PART 3 HEATER PIPING 8 A PLUMBING 8 B THERMAL EXPANSION 8 C CONDENSATION 8 D INSULATION BLANKETS 8 E TEMPERATURE AND PRESSURE RELIEF VALVE 9 F FILLING T...

Страница 4: ...causing a fire and or explosion or the release of mold bacteria or other harmful particulates into the air Operating a previously submerged water heater could result in property damage severe persona...

Страница 5: ...er containing chlorine in excess of 100 ppm Hardness 7 grains Chloride levels 100 ppm pH levels 6 8 TDS 2000 ppm Sodium 20 mGL Failure of electric elements due to lime scale build up on the heating su...

Страница 6: ...ns See Table 2 for a Listing of Available Elements ELEMENTS AND THERMOSTATS AVAILABLE WATTAGE VOLTAGE FULL LOAD CURRENT IN AMPS Single Phase 2 3 000 240 13 4 500 19 Table 2 Listing of Elements and Cor...

Страница 7: ...evere personal injury or death 2 Check for nearby connections to System water piping Electrical power Choose a location for the water heater as centralized to the piping system as possible 3 Check are...

Страница 8: ...n exceed the safety setting of the relief valve causing it to operate during each heating cycle This rapid and repeated expansion and contraction of components in the system can cause premature failur...

Страница 9: ...utlet and run to a safe place of disposal Terminate the discharge line in a manner that will prevent possibility of severe burns or property damage should the relief valve discharge Discharge line mus...

Страница 10: ...hould install a mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from your local plu...

Страница 11: ...maximum possible input allowable see Table 2 for listing of inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the w...

Страница 12: ...he wiring connections PART 5 INSTALLATION CHECKLIST WATER HEATER LOCATION YES NO Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Pro...

Страница 13: ...an and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal injury or death B THERMOSTAT ADJUSTMENT AND ECO...

Страница 14: ...ock STEP 2 Run hot water at a faucet in the system When it runs cold shut off the faucet Then shut off water at the main cold water inlet or if possible valve off the water heater from the system Drai...

Страница 15: ...iently over its service life The Owner User may perform the maintenance activities described below Monthly Every two weeks in hard water locations It is recommended that a few quarts of water be drain...

Страница 16: ...ected to the valve directing the flow of hot water from the valve to a proper place of disposal Replacement of the valve is required if no water flows when the lever is operated Turn the water heater...

Страница 17: ...2 Damaged seal ring washer 3 Gasket around heating element s 1 Tighten hex nut union fitting 2 Replace seal rings as required 3 Inspect and replace gasket if necessary Leaking Temperature and Pressur...

Страница 18: ...18 Figure 7 Parts Blowout...

Страница 19: ...19 NOTES...

Страница 20: ...s Date of Installation Installer s Code Name Product Serial Number s Comments Installer s Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer ha...

Страница 21: ...reach of warranty D If government regulations industry certification or similar standards require the replacement water heater or part s to have features not found in the defective water heater or par...

Страница 22: ...s purchased or the installer for assistance Be prepared to provide the retailer or installer with a copy of your original receipt complete model and serial numbers and the date of installation of your...

Отзывы: