22
User menu:
User menu
Text
Default
values
Min. value
Max. value
Explanation
Boiler parameters 1)
Set point temp.
65 °C
E.g. 65 °C 2)
E.g. 85 °C 2)
Desired boiler
temperature
Summer/winter
Winter
Winter
Summer
If summer is selected
the heating circuit
pump stops
Storage tank 3)
Set point temp.
70 °C
40 °C
80 °C
Desired storage tank
temperature
Hysteresis
15
°
C
1 °C
30 °C
Temperature less than
storage tank set point
at which heating starts
Hot water 3)
Hot water priority
No
No
Yes
Set to Yes gives
absolute priority for hot
water (heating circuit
pump stops when hot
water pump starts)
Legionella function
OFF
OFF
ON
-
Set point temp.
60 °C
30 °C
70 °C
Set point for the
temperature in the hot
water tank
Hysteresis
10 °C
1 °C
10 °C
Hot water pump
hysteresis
Low output
Fan level
22 %
1 %
100 %
Fan speed at low
output
Pellet volume
30 %
1 %
60 %
Operating time for
feeder motor at low
output
High output
Fan level
30 %
1 %
100 %
Fan speed at high
output
Pellet volume
60 %
1 %
60 %
Operating time for
feeder motor at high
output
Ignition
Fan level
30 % 4)
1 %
100 %
Fan speed at ignition
Pellet volume
15 sec
1 sec
60 sec
Operating time for
feeder motor at ignition
Light sensor
Current light strength
--
0
1023
Current light value
(cannot be set)
Minimum light strength 5)
10
0
1023
Min. light value for fire
in the fuel
Feeder auger filling
Do you want to start filling
the feeder auger?
Yes
No
Used for force-filling
the feeder-auger, e.g.
at start-up following a
dry run.
Time set
Time and date set
--
-
-
Set time and date
1) when selecting the extra sensor as storage tank sensor the set possibility of the boiler temperature disappears.
2) depends on the setting under ”SERVICE MENU”
3) either the storage tank or hot water menu point is displayed depending on the selection made under the ”Service menu”.
4) 30 % for burners with a blank fan; burners with black fan have a default value of 3% when the ignitor is mounted in a pipe of the
same length as the ignitor and 15% when the ignitor is placed in a long pipe.
5) the normal setting may vary; check the value (current light strength) when the light sensor is not working (take out the light
sensor and cover it if need be); the minimum light strength is set 5 to 8 points higher than the value in darkness.
Typical screen shots when setting values and changing setup: