3.3.2 Installation with thermostatically controlled domestic hot water production
1: TPK/Scandpell
2: Loading unit 55 °C (you could also use a thermostatic 3-way valve and pump – use a balancing valve on the shunt loop
3: Hot water tank VBF 85, VBF 100 or VBF 150
4: Thermostat with external sensor bulb
5: Expansion tank (the size should be adapted to the total volume of the system)
6: Safety valve
Please note that on this installation the summer/winter function cannot be used. To be set to winter
(standard set up).
Control unit set up:
Function of extra sensor is set to OFF (”Service menu”)
Pump function: Boiler pump (”Service menu”)
The boiler temperature is set by turning the rotary button
See also the functional description in 5.1.2.