Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD31 Series User Manual V1.1
―
79
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F08.08
Rotor resistance of motor
7.5kW above: 0.000 - 9.999Ω
Depend on
motor
0.001Ω
×
7.5kW and below: 0.00 - 99.99Ω
0.01Ω
F08.09
Leakage inductance of
motor
7.5kW above: 0.00 - 500.00mH
Depend on
motor
0.01mH
×
7.5kW and below: 0.0 -
5000.0mH
0.1mH
F08.10
Mutual inductance of
motor
7.5kW above: 0.00 - 500.00mH
Depend on
motor
0.01mH
×
7.5kW and below: 0.0 -
5000.0mH
0.1mH
F08.11
Idling excitation current
of motor
7.5kW above: 0.0 - 999.9A
Depend on
motor
0.1A
×
7.5kW and below: 0.00 - 99.99A
0.01A
F09: V/f Control Parameters, on pages 36 - 38
F09.00
V/f curve of motor
0: Line
1: Square curve
2: 1.2 exponential curve
3: 1.7 exponential curve
4: User-defined curve
0 1
×
F09.01
V/f frequency of motor
(F3)
F09.03 - F08.03
0.00Hz
0.01Hz
×
F09.02
V/f voltage of motor (V3)
F09.04 - F08.01
0V
1V
×
F09.03
V/f frequency of motor
(F2)
F09.05 - F09.01
0.00Hz
0.01Hz
×
F09.04
V/f voltage of motor (V2)
F09.06 - F09.02
0V
1V
×
F09.05
V/f frequency of motor
(F1)
0.00 - F09.03
0.00Hz
0.01Hz
×
F09.06
V/f voltage of motor (V1)
0 - F09.04
0V
1V
×
F09.07
Torque boost of motor
0.0 - 30.0%
0.0 : Auto torque boost
55kW and
below: 2.0%
75 - 132kW:
1.0%
0.1%
×
F09.08
Cut-off point used for
manual torque boost of
motor
0.0 - 50.0% (F08.03)
10.0%
0.1%
○
F09.09
Slip compensation gain of
motor
0.0 - 300.0%
100.0%
0.1%
○
F09.10
Slip compensation filter
time of motor
0.01 - 10.00s
0.10s
0.01s
○
F09.11
Slip compensation limit of
motor
0.0 - 250.0%
200.0%
0.1%
×
F09.12
Compensation constant
of motor
0.1 - 25.0s
2.0s
0.1s
○
F09.14
AVR function of motor
0: Disabled
1: Enabled all the time
2: Disabled in Dec process
1 1
○
F09.15
Oscillation-suppression
0: Depend on excitation current
0 1
○
A