Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
―
78
―
HD31 Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
corresponding value of
line 1
F05.05
Min. setting of line 2
0.0% - F05.07
0.0%
0.1%
○
F05.06
Min. setting
corresponding value of
line 2
0.0 - 100.0%
0.0%
0.1%
○
F05.07
Max. setting of line 2
F05.05 - 100.0%
100.0%
0.1%
○
F05.08
Max. setting
corresponding value of
line 2
0.0 - 100.0%
100.0%
0.1%
○
F05.09
Max. setting of polyline
F05.11 - 100.0%
100.0%
0.1%
○
F05.10
Max. setting
corresponding value of
polyline
0.0 - 100.0%
100.0%
0.1%
○
F05.11
Inflection point 2 setting
of polyline
F05.13 - F05.09
100.0%
0.1%
○
F05.12
Inflection point 2
corresponding value
0.0 - 100.0%
100.0%
0.1%
○
F05.13
Inflection point 1 setting
of polyline
F05.15 - F05.11
0.0%
0.1%
○
F05.14
Inflection point 1
corresponding value
0.0 - 100.0%
0.0%
0.1%
○
F05.15
Min. setting of polyline
0.0% - F05.13
0.0%
0.1%
○
F05.16
Min. setting
corresponding value of
polyline
0.0 - 100.0%
0.0%
0.1%
○
F05.17
Skip frequency 1
F00.09 - upper limit
0.00Hz
0.01Hz
×
F05.18
Skip frequency 2
F00.09 - upper limit
0.00Hz
0.01Hz
×
F05.19
Skip frequency 3
F00.09 - upper limit
0.00Hz
0.01Hz
×
F05.20
Range of skip frequency
0.00 - 30.00Hz
0.00Hz
0.01Hz
×
F08: Asynchronous Motor Parameters, on pages 35 - 36
F08.00
Rated power of motor
0.2 - 500.0kW
Depend on
motor
0.1kW
×
F08.01
Rated voltage of motor
0 - 999V
1V
×
F08.02
Rated current of motor
7.5kW above: 0.1 - 999.9A
0.1A
×
7.5kW or below: 0.01 - 99.99A
0.01A
F08.03
Rated frequency of motor
1.0 - 400.0Hz
50.0Hz
0.1Hz
×
F08.04
Rated RPM of motor
1 - 24000rpm
1500rpm
1rpm
×
F08.05
Power factor of motor
0.001 - 1.000
Depend on
motor
0.001
×
F08.06
Parameter auto-tuning of
motor
0: Auto-tuning is disabled
1: Stationary auto-tuning
2: Rotary auto-tuning
0 1
×
F08.07
Stator resistance of motor
7.5kW above: 0.000 - 9.999Ω
Depend on
motor
0.001Ω
×
7.5kW and below: 0.00 - 99.99Ω